b'OILCOP GEN II TANK MONITORING FLEXIBILITYOILCOP GEN II TMTANK MONITORING FLEXIBILITYOilCop Gen II Overfill Notification level, low level shutoff, high level warning and high level alarm Best practices dictate that above ground lube storage tanksconditions. The system can also be configured to control remote be provided with means for overfill notification. To fill thissolenoids and pump relays or, by using the available (normally FLUID MGMT. need, OilCop Gen II Tank Overfill Notification System has beenclosed) pneumatically operated shutoff valve to isolate the developed to provide all necessary components to ensure a tanksubject tank to prevent any further fluid introduction. This has overfill situation does not occur. the added advantage of eliminating the need to install and route wires to control air solenoids at the remote pump locations.The OilCop Gen II Tank Overfill Notification System providesOverfill alarms are provided via a 110 db audible alarm along with basic tank level monitoring as you would expect via visuala bright visual flashing strobe light. An acknowledgement switch and audible alarms. Additionally, OilCop Gen II Tank Overfillallows you to silence the audible alarm, the strobe light continues Notification System goes beyond the basics by also allowingflashing until the high level alarm condition is corrected.you to easily program and receive email notifications for reorder Tank Overfill Visual/Audible Alarm Module P/N950421-A1 NPTF Stainless Steel P/N100895 pneumatic valve.OILCOP GEN II TANK mONITOrING FLEXIBILITY Bright red strobe light flashes as a warning when the tank levelP/N950421-Breaches the preset High Level Shutoff level. Warning levels1NPTF Stainless Steel valveare set for each tank via the Product and Tank Configuration screen found in the OilCop Gen II Administration desktop setup.P/N950421-CSystem includes an acknowledge button to2 NPTF Stainless Steel allow silencing the audible alarmpneumatic valvewhile the strobe light continues to flash until the High Level condition has been corrected. Evacuation Pump TimersAudible alarm sounds at 110 dbThese Evacuation Pump Timers are adjustable between 3 and when fluid tank level reaches15 minutes and are used to Start/Stop air supply for double the preset High Level Shutoffdiaphragm evacuation pumps at used oil or used coolant level in conjunction with thepickup stations.visual strobe alarm on P/NP/N100570-C100895. The audible alarm canUsed coolant evacuation timer, set pump be silenced by depressing the Press tooperating on time by turning knob Silence Alarm located on the Tank Overfillclockwise between 3 and 15 minutes.Alarm Module. P/N100570-UUsed oil evacuation timer, set pump operating Pneumatic valves on time by turning knob clockwise betweenThese valves should be used with an air filter/regulator set3 and 15 minutes.between 80100 PSI for proper operation. They are engineered to ensure rapid valve closure since fluid flow assists the pneumatic operation Tank Overfill AlarmP/N 100895110 db SirenOIl TankFill Line Air Filter/RegulatorP/N 540104C OilCop Gen II Tank Monitor ModuleP/N 100920Air Supply Relay ControlPneumatic Valve Kit Tank Probe Monitor Tank Probe MonitorP/N 950421-A Relay ControlTank ProbeP/N 100881-06-2062 800.894.3572'