b'BULK TRANSFER PUMPSThe Pump Viscosity Chart shown below provides a general viscosity guideline for Liquidynamics 2 HP, 1 internal gear pumps when equipped with your choice of direct drive 1:1 gear reduction, 2:1 gear reduction or 4:1 gear reduction. BULK TRANSFERPUMP VISCOSITY CHART** Pump should be emptyFixed Gear PumpsPump Gear RatioTypical Operating Range to start2 HP 40 GPM1:1 Direct DriveUp to 230 Centipoise180 Centipoise and above2 HP 20 GPM2:1 Gear ReductionUp to 1600 Centipoise1500 Centipoise and above2 HP 10 GPM4:1 Gear ReducitonUp to 4900 Centipoise3500 Centipoise and aboveNOT RECOMMENDED5000 Centipoise and above** Pump should be empty to start column indicates the viscosity at which pump needs to be empty in order to start when pumping the higher viscosities noted in the Typical operating range column.NOTE: Pump Viscosity Chart and Table apply to P/Ns 33267, 33267P, 33267-20CG, 33267P-20CG, 33267-10CG, 33267P-10CG, 33380-V1, 33380-V2, 33265, 33265-20SG and 33265P-20SGNOTE: Use of the optional PowerMaster II greatly expands the viscosity pumping range by gradually slowing down the pumping rate to maintain amp draw below circuit breaker trip amperage.LUBRICANT VISCOSITY TABLEBULK TrANSFEr PUmPSTemperature100 F90 F80 F70 F60 F50 F40 F30 F20 F10 F0 FFLUIDISO No.38 C32 C27 C21 C15 C10 C4 C-1 C-7 C-12 C-18 CA.T.F35445672951271762503665448725w-20465976101136188268394598944155710w3237496487122176263407659112020125w-30617810113418225235952880112622070Hydraulic464661821141632413705929951763331910w-30709112116523033149175512052010351720w686892127181266405640105918433392665130w100100135187267392596940154726704854936410w-4097126168228317454669101716052635452315w-40123164223311445656998157525854437799940w15012817825337056288714572510455587651801520w-5016422230844064597615302494424375751426680W-9014319828241262297515912717488092751877050w220226321470709111018073074549110358207694459580W-14026335950272010621615254241527068125962362190w gear32033147971310991757292650999346181213741782894140w gear46047970210601658269345578077150652974562574141305Readings are in centipoise (formula used is centistoke X .9 = centipoise).Example of proper Chart usageExample #1: If you would like to pump 15w-40 motor oil at a minimum temperature of 20 F, the maximum viscosity at this temperature is 2,585 cps, which is in the green zone of the chart (as determined from the lower chart). Next, look at the green line in the upper chart to determine that you can pump this oil at 10 GPM by using a fixed gear pump (4:1 ratio).Example#2: If you need to transfer oil at 40 GPM, the lower chart shows that you can pump any of the oils in the orange range of the chart. For instance, 10w-30 motor oil can be pumped at 40 GPM down to 60 F. With the use of a PowerMaster, the pump will continue to pump 10w-30 at gradually lower pumping rates as the temperature decreases (viscosity increases).www.liquidynamics.com 85'