b'TANK MONITORINGP/N100550 P/N100552Self-contained, battery operated,TM3 shuts off pump air supply thus High/Low level Sentry tank monitor ispreventing tank overflow when a designed for use with single or doublehigh fluid tank condition occurs. It FLUID MGMT.wall above ground tanks. Float sensoris fully mechanical/pneumatic, with can be easily adjusted for sensorno electrical/electronic parts. Operating air depth from 2 to 10 and may be used to monitorpressure range of 50150 PSI. Designed for indoor interstitial space of double wall tanks. Whenuse with most single or double wall above ground activated to an alarm condition, the alarm soundstanks. For use with fluids such as fresh oil, used a 103 decibel siren for up to four days with a fresh 9oil, diesel fuel, antifreeze, water and other fluids volt battery. This unit is designed for indoor use forwith a high flash point.use with fresh oil, used oil, diesel fuel, antifreeze, water and other fluids with a high flash point. P/N100550-110Same as 100550 above, except it includes a 110VAC/12 Volt power source.P/N100550WThe Sentry tank monitor is designed to be wall mounted indoors and used with the included weather resistant float sensor located remotely on the tank to be monitored. Function of the tank TANK mONITOrINGalarm and float sensor is otherwise identical to P/N 100550 above. P/N100554LLow voltage solenoid valve for use with P/N 100551 Tank Monitor, shuts off pump air supply when the 007 Tank Monitor is in the alarm condition. May be located up to 350 away from the 007, includes a wall mounted 115 VAC/12 V transformer. Inlet/outlet ports are 1/2 NPTF, operating pressure range is 10P/N100551 200 PSI. For use with P/N 100551 007 Tank Monitor.The 007 Tank Monitor will sense either high or low P/N100554LTtank levels and will sound a 103 decibel alarm along with aSame as P/N 100554L except it includes an adjustable timer to flashing strobe light when activated. The 007 Tank Monitor canshut off pump, may be set within a 315 minute range.activate an optional solenoid valve P/N 100554L to shut off pump air supply when in an alarm condition. This unit is designed for indoor use for use with fresh oil, used oil, diesel fuel, antifreeze, water and other fluids with a high flash pointOverfill Warning Valve for Used Oil SystemsP/N100555-ASValve installs on 2 bung opening at top of used oil tank, air supply is routed through valve before going to the pump. Valve will close off pump air supply when liquid level reaches 90% of tank capacity diverting air to provide an audible signal.www.liquidynamics.com 63'